7.1 Messages
7 Operation
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
7-2
7.1.2 Signal statuses
Signal statuses7-Drehzahlwaechter_Signalzustnde
*) Status B only leads to a safe shutdown when the "broken shearpin
monitoring" option is activated (B2). If the option is not activated (B1),
only bit 9 of the diagnostic word will be set.
**) The speed output is "1" if the configured overspeed is not exceeded.
***) Input = 1: Speed monitor detects impulses
Input = 0: Speed monitor detects no impulses
****) For explanations of the speed monitor's diagnostic word, see the
PNOZmulti Configurator's online help
Encoder inputs
***)
Outputs Diagnostic word
****)
Status
Key
Incremental encoder track A
Incremental encoder track B
Proximity switch
Standstill
Overspeed, no fault on the speed monitor
Bit 9: Proximity switch fault
Bit 9: Incremental encoder fault
Bit 10: Frequency difference, track A and B
Entry in the error stack
A Standstill, no fault 0 0011 0000
B1
*)
Standstill, fault on proximity switch 0 0111 0100
B2
*)
Broken shearpin 00100 0101
C Standstill, unwanted signal change, track A 0 1011 0000
DRotating shaft, fault, track A 01100/1 **)0011
E Standstill, unwanted signal change, track B 1 0011 0000
FRotating shaft, fault, track B 10100/1 **)0011
GRotating shaft, fault at proximity switch 11000/1 **)1001
HRotating shaft, no fault 11100/1 **)0000