Installation / Preparation for commissioning
28
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland
Telefon +49 711 3409-0, Telefax +49 711 3409-133, E-Mail: [email protected]
English
5.5.1 Supply voltage, X1
NOTICE
Risk of undetected damage to the internal
electronics due to incorrect overvoltages!
If an overvoltage of >36 VDC is applied inadvertently,
the measuring system must be inspected on site.
The measuring system must be taken out of
service immediately
If returning the measuring system, the reasons or
circumstances under which the overvoltage
occurred should be stated
The power supply must satisfy the requirements
in accordance with SELV/PELV (IEC 60364-4-
41:2005)
PIN Signal Description
1 + 24 VDC (11…28 VDC) Supply voltage
PIN 1/2
through-connected
2 + 24 VDC (11…28 VDC) Supply voltage
3 0 V GND
PIN 3/4
through-connected
4 0 V GND
Optical sensing unit and magnetic sensing unit have a common supply, but are
electrically isolated internally via two separate power supplies.