8.2 Operating notes
8 Operation
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
8-2
8.2Operating notes8200Operating notes8-
8.2.1 Switch on PSENvip
Switch on PSENvip8-Betrieb_PSENvip_einschalten
The PSENvip is ready for operation once supply voltage has been ap-
plied and the self test has been carried out.
Switch on the supply voltage.
A self-test runs while the start screen is displayed on screen.
An error message will appear if an error is detected.
Fig. 8-1: Display after power-up
8.2.2 Muting lamp
Muting lamp8-Betrieb_Mutinglampe
Muting lamps warn of residual hazards associated with the safeguard.
8.2.3 Initial press stroke
Initial press stroke8-Betrieb_Erster_Pressenhub
When the initial press stroke occurs after the machine is switched on, a
function test must be carried out on the PSENvip, using the test piece.
Set standard protected field mode.
INFORMATION
Information on the error that has occurred and how to rectify it
can be found in the chapter entitled "Diagnostics and Trouble-
shooting".
Rectify the error.
If no error has been detected, the display will show the status of
the OSSD and the protected field mode that is currently
selected, which is standard in the example.
SYSTEM OK
OSSD ON
NORMAL OPERATION
Kommentare zu diesen Handbüchern