Installation
OperatingManualPNOZmB0
1002660EN03
16
INFORMATION
Pleasenotethatatthestatedminimumdistance,itwillbedifficulttoswap
thechipcardfromabove.Ifyoucannotleaveagreaterdistance,remove
theunitfromthemountingrailtoswapthechipcard.
5.3 Connectingthebaseunitandexpansionmodules
Pleaserefertothedocument"SystemExpansion"fordetailsofthenumberofmodulesthat
canbeconnectedtothebaseunitandthemoduletypes.
Themodulesarelinkedviajumpers.
}
Removetheterminatoronthesideofthebaseunitandontheexpansionmodule.
}
Installthebaseunitandexpansionmodulesonthemountingrailandconnecttheunits
usingthejumpersupplied
}
Fittheterminatortotheunconnectedinterfacesonthebaseunitandexpansionmod
ule.
Terminator Terminator
IM0
IM1
IM2 I6
I5
I4IM3 I7
I8
I10 I14
I13
I12I11 I15
X3
X1
X4
X2
PNOZ mm0.1p
T0
T1
T2 O2
O1
O0T3 O3
IM16
IM17
IM18 0 V
A2
A1IM19 24 V
M20
M21
M22 M23
Jumper
CAUTION!
Onlyconnectthebaseunitandexpansionmoduleswhenthesupplyvoltage
isswitchedoff.